摘要:莱钢热电厂两台给水泵为锅炉供水关键设备,其润滑油站主要用于主机给水泵电动机轴承摩擦部位供送润滑
油。本文通过远程DCS控制系统自动逻辑运算,实现润滑系统自动联锁控制策略,显著特性动态快速响应、提升自动化控制
水平、有效可靠保护主机的安全。
关键词:控制系统;润滑;给水泵
DOI编码:10.14016~.cnki.1001.9227.2015.03.167
Ab— The two pumps for the water supply was the key equipment of the boiler in Laiwu Steel Thermal Power Plant.The lubficating
oil station is mainly used for the host feed pump motor bearing friction parts supplying lubricating oil.In this paper,by
means of remote DCS control system of automatic logic operation,it realized the automatic interlock control strategy of lubrication
system,the dynamic characteristics of fast response.It significantly enhanced the security level of automation control,efective and
reliable protection of the host.
Koy :Control system;Lubrication;Supply Pum p
中图分类号:TP273 文献标识码:B 文章编号:1001—9227 (2015)03—0167—02
0 前言
DCS系统采用现场层(远程IO),控制层(cPu)和管理层(工业
计算机)组成的三级控制系统来实润滑油站自动控制n 。硬件主
要是由监控单元、控制系统、检测部分和执行部分等组成。检
测单元远程IO实现现场数据的采集和上传,控制系统CPU完
成逻辑处理和控制任务实现设备的自动启停、PID回路的自动
调节等功能,监控单元工业计算机利用友好人机界面实现人机
对话和远程监控显示,数据归档和报警提示功能 。
1 DCS远程控制策略
(1)采集过程数据准确及时,对数据进行处理、转换;信号
进行了隔离、滤波处理,因此具有较高的抗干扰能力
(2)顺序逻辑控制确保安全、正常和灵活。输出过程操作命
令快速响应,调节控制确保安全、实用。
f3)手动、自动灵活方便操控。
(4)加强调试、测试和报警功能,增强系统的安全性和灵
活性。
(5)承担与过程控制级的数据通讯,对现场控制级的设备进
行监测和诊断。
2 主机给水泵与润滑站系统的联锁控制
机组在运行期间,一旦因润滑站系统故障引发主机给水泵
停止工作,会直接造成磨损主机轴承,锅炉上水不及时导致主
体设备损害、停炉、发电机停机事故,故主机给水泵与润滑站
润滑油系统的联锁控制逻辑要求严密,对于润滑油泵之间的压
力联锁传感器模拟量一次原件选用可靠性高智能的EJA变送
收稿日期:2015—0卜O7
作者简介:郭勇(1976一),男,汉族,山东菏泽人,工程师,主
要从事冶金自动化研究工作。
器,开关量压力开关采用图尔克智能带显示的电子压力开关,
可就地观察油压的变化。考虑到主机润滑连续性和安全,设计
充分考虑均安装在油泵出口母管处,最直观的监控油压状况,
联锁反应动作时间精短。
润滑油站共有两台油泵,监控操作画面内,远程驱动能实
现两台稀油泵任一台的手动启动、停止;联锁控制方面既能实
现两台油泵电气联锁互备,同时设计自控联锁启停备泵。
(1)油泵手动控制时监控切人手动按钮,任选油泵可随意投
入工作。
(2)切人连锁控制时:
① 电气联锁在主泵发生故障时,润滑油泵接到运行指令后
接触器未动作或油泵电机过载、短路跳闸时,画面稀油泵运行
指示灯闪烁报警,备泵投入联锁自动启动。在备用泵投入运行
后将工作泵从系统中切除,待故障处理完毕后将工作泵处于备
用状态。
② 仪控联锁选择主泵运行后,油站压力降低到50KPa设定
值下限时,备用泵自动启动,如果继续下降到20KPa压力值下
限,同时电子式压力开关发出压力低低重故障报警,持续1秒
后程序判断联锁停给水泵,从而实现对其主机设备联锁保护。
用数字量和模拟量双信号控制逻辑与判断可有效消除单体数据
采集设备因信号干扰误报的隐患发生,造成主机设