提要] E绕大跨度预应力混凝十转换梁工程,建立了空间计算模型.优化了结构平面布置,着力讨论了楼
板、结构自重、预应力张拉施工方案等因素对预应力转换梁抗裂验算的影响,以及预应力在复杂结构中对周边
构件受力的改变,提出了在设计中应注意的问题及相应措施。
[关键词] 预应力 框架 转换梁
Analysis on Frame Structure with Prestressed Reinforced Concrete Transfer Beam/Wu Zhehua1-2, He Libo7, Xu
ouoping , Zhang Bing (1 Department of CIVH|Enginecning, 1ong University , Shanghat 200092, China: 2 Ningbo
Architectural Design and Rescarch Institule, 315010,China)
Abstract:Focus on projeet of long span prestressed concrete transler beam, the spatial calculated models are built. The
structural plan anmgernent is oplmized . some factors such as floor rnembers, self-weight of structure, construction process of
prestressing having influence upon cracking capacity are discussed. Mechanics of periphery mernbens are changed according
with prestressing im sophisticated structure . The design method is put forward to satisfy the techmical spocification .
Keywords:prestressed;Irarme ; transler beam
1
问题的提出
12300
路径1
宁波江南路会所是一栋四层休闲与办公相结合的
多功能建筑。建筑总面积约1.3万m7。东南侧有一室
内游泳池穿插于主体结构中,位于主体结构层3楼面
44
下方,如图1,2所示。由于游泳池的布局在主体结构
层3楼面设置预应力转换梁来承托上部两层楼面,屋
面和顶棚的荷载。如何针对结构在施工和使用阶段实
际的受力情况进行结构合理布置,确定预应力度,做好
预应力得额土转换累 YKL-1
预应力张拉施工方案的安排成为工程结构设计的关
键。工程属于丙类建筑,抗震设防烈度为6度,场地土
类别Ⅲ类,设计地震分组为第一组。
预应力淘凝土转换聚YKL-2
2 计算模型
转换梁 YKL-I,YKL-2的跨度 L分别为17.35,
21.77m,截面分别为800x1800,800 x 2 000。转换梁
两端框架柱截面为1000×1000。现浇楼板板厚
图Ⅰ 层3局部结构平面布置
100mma 图 1 阴影部位的梁、板、柱混凝土强度等级为
位构件对预应力设计影响较小,不予考虑。应用在
C40。楼面、屋面活载(标准值)分别为2.5,2.0kN/m7。
ANSYS8.1基础上开发的PD程序建立了仅阴影部位的
活载准永久值系数为0.5。抗裂等级为二级。选用有
空间结构计算模型,其中是否考虑楼板对预应力施加
粘结低松弛预应力钢绞线 ∮15.2,抗拉强度标准值 /
影响的整体计算模型如图 3 所示。模型中梁、柱选用
=1 860N/mm?,预应力筋张拉控制应力。。为0.70/ ,
Lagrange 插 值函数的2节点一维梁单元;楼板选用
一端张拉,预应力损失为23.2%。”预埋波纹管,采
Mindlin 板单元和平面应力单元组合而成的4节点二维
用抛物线形与直线形混合布筋。其中抛物线形反弯点
壳单元。同时也建立了相应的各施工阶段的计算模型。
分别在0.116L和0.131L处。为进行预应力混凝土转
3 转换梁部位结构的优化
换梁的设计,根据工程经验判断紧邻转换梁跨的周边
以图3不考虑楼板的纯框架结构为整体计算模
构件对预应力设计有影响,如图Ⅰ阴影部位:而其他部
型,计算了在荷载标准组合下转换梁梁上柱的数量和
因本站资料资源较多,启用了多个文件服务器,如果浏览器下载较慢,请调用迅雷下载,特别是超过了5M以上的文件!请一定调用迅雷,有时候速度就会飞起哦,如果您的浏览器自动加载了PDF预览,文件太大又卡死,请按下载说明里的把PDF插件关闭了就可以直接下载,不会再预览了!