Scope
This document describes a test method to determine the volume and weight changes of injection products
used for swelling fitted filling of cracks, voids and interstices after air drying and water storage cycles.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 196-1:1994, Methods of testing cement - Part 1: Determination of strength.
EN 1504-1:1998, Products and systems for the protection and repair of concrete structures-Definitions,
requirements, quality control and evaluation of conformity - Part 1: Definitions.
prEN 1504-5:2001, Products and systems for the protection and repair of concrete structures - Definitions,
requirements, quality control and evaluation of conformity - Part 5: Concrete injection.
Terms and definitions
For the purposes of this document, the terms and definitions given in EN 1504-1.1998 and prEN 1504-5:2001
apply.
Test principle
The volume and weight changes which occur during air drying and water storage,from 24 h after casting and
onwards,are measured on prismatic specimens having dimensions of 5 mm x 40 mm x 160 mm.
Apparatus
1
5.1 Moulds complying with the requirements of 4.5 of EN 196-1:1994.
5.2 Apparatus for measuring the dimensions of the test specimens to an accuracy of 0,1 mm.
5.3 Balance capable of weighing 500 g to an accuracy of 0,01 g.
5.4 Water bath containing potable water for completely immersing the test specimens at a temperature of
(21±2) ℃ The volume of the water bath is chosen to comply with requirements in 7.3.4.
5.5 Storage room for conditioning the test specimens,at a temperature of(21±2)°Candarelative
humidity of (60±10) %.
5.6
Support grid for supporting the specimens with a minimum of 5 mm clearance in a water bath or in air.
5.7 Air oven capable of maintaining the specified temperature to ±2 ℃. The oven shall be fitted with
forced-ventilation equipment