[提要] 通过一个强震软土区全轻骨料混凝土结构的工程实践,分析了轻骨料混凝土的材性特点在工程中的
实际反应和影响,提出在轻骨料结构工程应用中应注意工程的地方性和差异性,扬长避短,以充分发挥轻骨料
混凝土这一新型建材优越的综合性能。
[关键词] 轻骨料混凝土 材性 抗震性能
设计程序
Application of Lightweight Aggregate Concrete Frame Structure in High Seismic Intensity and Soft Soil Site/Zhong
Yang,Jiang Xi(Yunnan Construction Design Institute,Kunming 650041,China)
Abstract: Based on the analysis of lightweight aggregate concrete character, an all-lightweight-aggregate-concrete frame
structure was build successfully in high seismic intensity and soft soil site. The differences between the lightweight aggregate
concrete frame structure and the normal RC structure are analyzed. And the problems are pointed out that should be paid
attention to in the engineering practice.
Keywords:lightwcight aggregate concrete; anti-seismic performance;material character;design software
工程概况
云南省建工医院C幢住院楼工程位于昆明盆地西
部滇池周边软土地区,标准层平面见图1。原设计为
四层普通混凝土框架结构综合楼,抗震设防烈度为8
度。基础(桩基及承台,承台顶标高为-1.900m)已于
1998年底施工完毕,后因故停工数年,2002年业主将建
筑使用功能改变为医院住院部,并要求增建一层成为
五层(局部楼梯间为六层),首层为食堂和救护车车库,
层高为4.8m;层2-5为病房,层高为3.3m,总建筑面
积为3 201m”。
工程地基土层分布情况及物理力学特性见表1,
图 1
标准层平面
.
属于典型的滇池周边湖相沉积软土地基,无液化土层。
值提高约 15%。即便如此,原设计的工程桩基承载力
已施工的工程桩为 9500 沉管灌注桩,桩长 22m,桩端
仍不能满足改造增层后的荷载要求,尤其在建筑中部
进人层⑥不小于900mm。桩基及承台平面布置见图2。
的重载框架柱下,尚需考虑群桩效应对工程桩承载力
工程桩施工后于1998年11月共进行了四组静载试验,
的折减,差距更大。
单桩竖向极限承载力标准值分别为520,706,867,
549kN,原设计取用了四组试桩结果的平均值660kN作
地基土层分布及物理力学特性
表 1
为单桩竖向极限承载力设计值。在该工程决定改造
土层
层厚(m)
E(MPn)
F.(kPa)
P (kP)
y(kN/m3)
后,考虑到原工程桩已施工三年半,土体的恢复和固结
①耕植土
1.0
②粘土
2.0
5.0
18.4
21
对其承载力的提高是有利的,为了检验桩的时间效应
③泥炭质土
4.0
1.5
13.8
11
以便充分利用其承载力,设计方又要求对两个废弃承
④粘土、粉质粘土
7.0
4.5
18.5
23
1 400
台破除进行试桩,2003年5月新增的两组试桩单桩竖
⑤粘土
8.1
4.0
18.1
30
1 500
向极限承载力标准值分别为900,980kN,与原试桩结果
⑥粉土、粉砂
末钻穿
6.8
18.7
26
1 700
相比有一定提高;考虑到滇池软土地区土层和试桩结
果的普遍不均匀性,最终采用了全部6组试桩极限承
*云南省科技厅 2001 年省院校科技合作项目;高性能轻骨料混凝土
载力标准值的平均值 754kN 为设计取用值,比原设计
的成套应用技术项目。
因本站资料资源较多,启用了多个文件服务器,如果浏览器下载较慢,请调用迅雷下载,特别是超过了5M以上的文件!请一定调用迅雷,有时候速度就会飞起哦,如果您的浏览器自动加载了PDF预览,文件太大又卡死,请按下载说明里的把PDF插件关闭了就可以直接下载,不会再预览了!