根据实际工程中力的传递路径简短的原则 ,通过对无梁楼盖配筋形式的分析比较 ,剖析传统配 筋形式存在的问题 ,探讨更合理更经济的无梁楼盖的配筋形式 ,以节约钢材 ,使结构构件受力更合理 ,从而推 广无梁楼盖的应用。 关键词 : 无梁楼盖 配筋形式 传力路径 预应力钢筋
DISCUSSION ON REINFORCING BAR ARRANGEMENT MANNER OF
PRESTRESSED2CONCRETE SLAB2COL UMN SYSTEM
Zhong Chunling Zou Chaoying
(Harbin Institute of Technology Harbin 150090)
Yin Xinsheng
(Jilin Institute of Architectural Engineering Changchun 130021)
Abstract : A more rational and economic rebar arranging manner for a prestressed2concrete slab2column system is explored
through a comparison and a analysis of the defects of the traditional method of rebar arrangement according to the principle
that the transferring route of the forces should be brief , in order that steel can be saved and the force on a structural member
be more reasonable , thus popularizing the use of the slab2column system.
Keywords : slab2column system reinforcing bar arrangement manner force2transferring path prestressed tendon
3 吉林省计划委员会资助项目。 3 3 尹新生同志为第二作者。 第一作者 :钟春玲 女 1973 年 11 月出生 硕士 收稿日期 :2002 - 07 - 22
0 引 言 预应力混凝土无梁楼盖已广泛应用于多、高层建筑楼盖 中 ,与其他的楼盖形式相比 ,预应力混凝土无梁楼盖有以下 几个突出的优点 :1) 减少构件截面 ,降低层高 ;2) 扩大柱网 , 增加使用面积 ;3) 节省材料 ,减轻结构自重 ;4) 能提供大空 间 ,间隔灵活 ;5) 在总高度不变的情况下 ,可通过增加层数来 平衡其增加费用 ,故仍可获得较可观的经济效益。因此 ,近 年来在建筑工程中 ,应用预应力混凝土无梁楼盖的结构大有 增加的趋势。而且 ,人们也正通过各种科学研究试图寻找一 种更合理的配筋形式 ,以便达到节约材料 ,节省造价的目的。 1 预应力混凝土无梁楼盖配筋形式探讨的现状 传统的预应力混凝土无梁楼盖形式可大致归纳为以下 4 种(图 1~图 4) : 许多科研工作者在传统配筋形式的基础上进行过许多 改进 ,取得了良好的受力效果和经济效益。但其改进的方案 仍然没有脱离这种横平竖直的配筋形式。 比较传统配筋形式 ,我们不难发现它们存在一个共同的 特点 ,即它们或多或少地还没有脱离以前梁板体系的设计思 路 ,其所采用力的传递路径基本是一样的 ,即外载 →楼板(跨 中板带) →梁(柱上板带) →柱子 →基础。也就是说 ,作用在 图 1 按柱上板带和跨中板带布置 楼板上的荷载都是通过梁(柱上板带) 而进行转换 ,然后才能 向下传递(如图 5 所示) 。 由此可见 ,传统的配筋形式 ,力的传递路径虽较明确 ,但 不够简捷。 2 沿对角线配筋方案的提出 力的传递路径除明确外 ,尚需简捷。而最简捷的传递路