本文结合 下坂地水利枢纽工程 实际应用,对影响水工沥青混凝土静三轴试验结果的温度 、加
载速度 、围压三大因素进行研究分析 ,得 出了温度 、加载速度 、围压三大因素对水工沥青混凝土静三
轴试验 结 果的影 响规律 。
关键词 :水工沥青混凝土;静三轴试验;初始模量;下坂地水利枢纽工程
中图分类号 :TV41(245) 文献标 识码 :B 文章编号 :1000—0860(2012)10.0016.03
Analysis on result of static tri-axial test on core sam ple from asphalt concrete core-wall of
Xiabandi Water Control Project
FAN Shuguang ,W ENG Changguo
(1.Xinjiang Xiabandi Water Control Project Construction Administration,Kashi 844000,Xinjiang,China;
2.Gezhouba Testing Co.,Ltd.,Yichang 443002,Hubei,China)
Abstract:In accordance、vith the actual application to the construction of Xiabandi Water Control Project.the three key factors
those impact the resuh from the static tri—axial test on the hydraulic asphalt concrete,i.e.temperature,loading rate and confining
pressure,are analyzed and studied herein,and then the laws of their impacts Oil the resuh from the test are obtained.
Key words:hydraulic asphalt concrete;static tri—axial test;initial modulus;Xiabandi Water Control Project
1 引 言
沥青混凝土是一种典型的粘弹塑性综合体 ,在小
变形范围内为线性粘弹性体 ,在大变形流动范围内表
现为粘塑性体 ,而在过渡范围内则表现为一般粘弹性
体。工程中需要采用 沥青 混凝 土非 线性参数进行演
算 ,参数一般用静三轴试验确定。影响静三轴试验结
果的因素众多,本文结合新疆下坂地水利枢纽工程拦
河坝碾压式沥青混凝土心墙芯样静三轴试验,分析探
讨温度 、加载速度 、围压三大因素对水工沥青混凝土
静三轴试验结果的影响规律 。
2 试验 方法及项 目设计
试验根 据 《水 工 沥 青 混凝 土试 验 规 程》(DIJT
5362--2006)相关条文进行。芯样尺寸切割为 100 mln
x200 inn,试件在设定温度条件下恒温大于 24 h,按
16
设定变形速率进行静三轴试验。试件在围压条件下稳定
30 min后进行轴向加载,通过传感器用计算机采集试件
加载过程中的轴向力、轴向位移和体变位移 ,再由试件
面积、高度和体积计算出试件的轴向应力、轴向应变和
体积应变。沥青混凝土芯样静三轴试验项 目见表 1。
3 试验结果
3.1 试验 温度 为 3.4℃的静 三轴 试验 结果
3.1.1 加载速度 0.2 mm/min和不 同围压条件的三
轴 试验
沥青混凝土静三轴试验结果见表 2、表 3。
3.1.2 加 载速 度 0.05 mm/min的三 轴试验
沥青混凝土静三轴试验结果见表 4。