摘要:对不同强度等级砂浆砌筑的混凝土多排孔砖砌体进行抗剪性能试验。结果表明,混凝土多排孔砖砌体的抗剪强度明显高
于烧结普通砖、烧结多孔砖和混凝土砌块砌体。提出了混凝土多排孔砖砌体的抗剪强度平均值计算公式 ,m=O.388v: 及抗剪设计
值的建议取值。
关键词:混凝土多排孔砖;砌体;砂浆强度:抗剪强度
中图分类号:TU502~.6 文献标识码:A 文章编号:1001—702X(2011)06—0028—03
Experimental study on shear property of masonry made of concrete multi—rOW hole bricks
HU Shang,HUANG Bangbiao,ZHU Jizhen,DU Yundan,JING Jiahua,ZHANG Xianghua,WANG Too
(Department of Civil and Architecture Engineering,Guangxi University of Technology,Liuzhou 545006,Guangxi,China)
Abstract:Shear properties of masonry made of concrete multi—row hole bricks with mortar of different strength grade were
tested.The results show that the shear strength of the masonry made of concrete multi-row hole bricks is obviously higher than
that of the masomT made of fired clay brick,fired porous brick and concrete block.The calculation formula for average shear st
rength value of the masonry made of concrete multi-row hole bricks,i , =O.388 X/fi is put forward and the suggested shear st
rengtb design va]ue is given.