后装拔出法检测混凝土强度测强曲线
的试验与研究
张雪丽 ,徐宏伟 ,姜 俊2,沈先荣 ,朱庆明2
(1.杭州广播电视大学城建学院,310012,杭州I;2.杭州建工建材有限公司,311107,杭州)
摘 要:通过对不同强度等级和不同龄期的混凝土进行后装拔出力与抗压强度对比试验,建立了后装拔出
法检测混凝土强度测强曲线的主要试验研究成果,该测强曲线可在符合一定条件的混凝土强度推定时使用。
关键词:后装拔出法;检测;混凝土抗拔力;混凝土抗压强度;关系曲线
中图分类号:TU722.2 文献标识码:A 文章编号:1000—4726(20l2)06—0551-03
EXPERⅡ ENTAL RESEARCH FoR TEST oF CoNCRETE CoM PRESSIVE
STRENGTH CoNVERSIoN CURVE BY PULL—oUT M口EcTHoD
ZHANG Xue-li’,XU Hong-wei’,JIANG Jun ,SHEN Xian-rong’,ZHU Qing-ming
(1.Hangzhou Radio and TV University City College,310012,Hangzhou,China;
2.Hangzhou Construction Building Materials Co.,Ltd.,31 1 107,Hangzhou,China)
Abstract:Tests are carried out to compare post-install pull-out force and compressive strength of concrete
at different strengths and different curing ages and main test and research results are obtained for examination
of concrete strength measuring curve by post-install pull-out method.The strength measuring curve may be
used when concrete strength meets certain conditions.
Key words:pull out method detected;detection;concrete anti-pull force;concrete compressive strength;
conversion curve
后装拔出法检测既有建筑结构实体混凝土强度
是指在已硬化的混凝土表面钻孔、磨槽、嵌入锚固件
并安装拔出仪进行拔出试验,测定极限拔出力,根据
预先建立的拔出力与混凝土抗压强度之间的关系检
测混凝土强度。它具有破损小、测试结果可靠及适应
范围广(混凝土强度等级在10—80MPa)等特点。
本文通过对不同强度等级和不同龄期的混凝土
进行后装拔出力与抗压强度对比试验,初步建立了后
装拔出法检测混凝土强度测强曲线。
1 混凝土组成材料、配合比与强度等级
经过大量调查,本试验选择了某公司生产的预拌
混凝土,该预拌混凝土强度等级涵盖面大、应用广、原
材料来源具有代表性,本试验研究所使用的各强度等
级混凝土配合比及应用部位如表1所示。
2 试件制作与养护
2.1 制作
根据《后装拔出法检测混凝土强度技术规程》
收稿日期:2012—04—21
作者简介:张雪丽(1973一),女,浙江杭 『、IX ,讲师,e—mail:zxl@mail.hzrtvu.
edu.ca.
(CECS69:1994)对建立测强曲线的基本要求规定:“建
立测强曲线试验用混凝土,不宜少于6个强度等级,每
个强度等级不应少于6组,每组至少可布置3个测点的
因本站资料资源较多,启用了多个文件服务器,如果浏览器下载较慢,请调用迅雷下载,特别是超过了5M以上的文件!请一定调用迅雷,有时候速度就会飞起哦,如果您的浏览器自动加载了PDF预览,文件太大又卡死,请按下载说明里的把PDF插件关闭了就可以直接下载,不会再预览了!