高层混凝土结构的梁刚度放大系数的讨论
郭远翔 ,林训潮
(1.华南理工大学土木与交通学院,广东广州510641;
2.华南理工大学建筑设计研究院,广东广州510641)
摘要:梁刚度放大系数从新规范颁布至今实际上还是一个比较模糊的概念,还没有明确、清晰地被广大设计人员
理解和接受。围绕梁刚度放大系数,采用Midas Building和PKPM对结构不同参数和构件内力进行分析比较,以此
进一步加深对梁刚度放大系数的认识。
关键词:梁刚度放大系数;有效翼缘;自振周期;侧移;内力
中图分类号:TU 37 文献标志码:A 文章编号:1008—1933【2015)04—012—05
Discussion on am plification factor for beam stifness
of high-rise concrete structure
GUO Yuanxiang .LIN Xunchao
(1.School of Civil Engineering and Transportation of SCUT,Guangzhou 5 10641,China;
2.Architectural Design Research Institute of SCUT,Guangzhou 510641,China)
Abstract:Amplification factor for beam stiffness has been a fuzzy concept since the issuance of new code.It is not well comprehended
by designers.Centering on the amplification factor for beam stiffness,use Midas Building and PKPM software to compare its effect to
structure parameters and internal force,in order to further deepen the understanding of the stiffness amplification factor.
Key words:amplification factor;effective flange;natural vibration period;lateral displacement;internal force
U 刖 吾
在框架梁的受弯内力计算中,是否应计人板及
其板筋的贡献此前一直是学术界及工程界讨论的一
个问题。
在多、高层混凝土结构中,为了提高结构的整体
性,将楼板与框架梁、柱整体浇筑,使得楼板在框架
梁的抗弯承载力中有贡献。这样就造成以往不考虑
楼板按矩形梁计算设计梁的抗弯及配筋存在较大误
差。这种误差主要体现在两个方面:一方面,梁和板
共同组成T形截面抗弯,受压翼缘的存在使得受压
区高度减小,在同样的外部荷载作用下,所需的受拉
钢筋减少;另一方面,在文献[1]整浇梁板的框架节
点抗震试验研究中发现,在框架梁端,板内钢筋对框
架梁抗弯约有30% 的贡献。因此,如果不考虑楼板
对框架梁的刚度及其承载力放大作用,实际上,框架
梁的配筋量将超出原承载力需要,部分钢筋不屈服,
最终形成强梁弱柱,不符合抗震要求。
收稿日期:2014-07~1
作者简介:郭远翔(1964一),男,广东潮安人,教授级高级工程师,硕
士,研究方向:高层结构设计、岩土工程设计。
E —m ail:1051488847@ qq.conl
对此,JGJ3—2010《高层建筑混凝土结构技术规
程》的5.2.2条_2 指出,在结构内力与位移计算中,
现浇楼盖梁刚度可考虑翼缘的作用予以增大。近似
考虑时,楼面刚度放大系数可根据翼缘情况取1.3
~ 2.0。
同时,GB50010-2010《混凝土结构技术规范》
的5.2.4条 指出,对现浇楼盖和装配整体式楼盖,
宜考虑楼板作为翼缘对梁刚度和承载力的影响,同
时提出梁刚度增大系数的概念。对于中梁按T形
截面受弯计算,而对于边梁按L形截面受弯计算。
相应的翼缘计算宽度6 见表1。