钢结构砂仓内侧混凝土
防腐耐磨损层工程实践
Engineering practice of concrete corrosion——resistant and
wear—resistant layer inside the steel sand bin
姜浩刚,刘 鹏(山东黄金矿业股份有限公司焦家金矿,山东莱州261441)
摘要:结构防腐主要从混凝土内部分析其腐蚀性,并通过掺入外加剂进行有机补偿,使其应用于各种抗裂防渗混凝土。焦家
金矿寺庄矿区砂仓采用钢结构仓壁内侧混凝土护壁防腐,取得了很好的效果。
关键词:防腐混凝土;钢结构;耐磨性
Abstract:The construction corrosion—resistant should mainly consider the corrosiveness in concrete interior,and the organic
compensation was performed by adding admixtures,and which make it appropriate to apply in various crack resistance and
impermeable concrete.Concrete corrosion—resistant layer inside the steel bin was used in Shizhuang mine area of Jiaojia gold mine,
and good effect was obtained.
Key words:corrosion resistant concrete;steel construction;wear resistant
1 —日j』j『一—舌—一
焦家金矿寺庄矿区生产规模不断扩大,原有的简易
充填站已经不能满足现在的生产需要,为了扩大生产,
2010年在焦家金矿寺庄矿区新建设一座1 O00m 钢结构
充填砂仓,由于寺庄矿区井下水氯离子含量非常高,达
到16 O00mg/L,如果单纯采用钢结构砂仓,井下水氯离
子对钢结构的腐蚀影响很大,混凝土结构的砂仓施工难
度大、容易出现渗漏、工期长,因此砂仓主体决定采用钢
结构与钢结构仓壁混凝土护壁耐磨损的方法。
2 设计方案
2.1 钢结构仓壁防腐蚀方案
钢结构仓壁防腐蚀方案见图1。
研究防腐技术的目的在于使结构物从投入使用到
钢结构仓壁开始锈蚀的时间尽可能的接近设计寿命。
要想完全避免Cl一的腐蚀,最理想的方法就是从根本上
保证钢结构仓壁与氯盐环境隔绝,事实上这不可能实
现。可行的是有效地控制氯盐的总量,使之限定在规定
的范围之内。依据钢结构仓壁在氯盐环境中电化学行
为的研究和腐蚀机理,凡是能有效阻止混凝土pH值下
降、保证钢结构仓壁界面上的钝化膜不活化、维持界面
双电层的电位恒定、避免钢结构仓壁表面去极化,就能
有效地控制腐蚀。
(1)严格检测、增厚保护层。质检部门应把“新拌砂