【摘要】 斜井滑模混凝土配合比设计优劣对于混凝土施工质量、进度起着非常重要的作用。福建仙游抽水蓄
能电站对从设计到实施阶段的斜井滑模混凝土配合比,结合现场施工等实际情况进行了优化,其合理性通过后
续施工得到验证。本文着重对仙游抽水蓄能电站斜井滑模混凝土配合比设计及优化进行分析总结,以供类似工
程借鉴。
【关键词】 配合比;设计;优化
中图分类号:TV212 文献标识码:A 文章编号:1673-8241(2015)08-0046-07
Design and optimization of inclined shaft slipform concrete mixing
proportion in Fujian Xianyou Pumped Storage Power Station
CHEN Bing,ZENG Yu
(Sinohydro Bureau 1 6 Co.,Ltd.,Fuzhou 350003,China)
Abstract:Design quality of inclined shaft slipform concrete mixing proportion is very important in concrete construction
quality and progress.Inclined shaft slipform concrete mixing proportion of Fujian Xianyou Pumped Storage Power Station is
optimized according to site construction and other practical condition.And its rationality is verified through subsequent
construction.In the paper,design and optimization of inclined shaft slipform concrete mixing proportion in Fujian Xianyou
Pumped Storage Power Station are emphatically analyzed and summarized,thereby providing reference for similar projeets.
Key words:mixing proportion;design;optimization
1 概述
福建仙游抽水蓄能电站装机容量120万kW,电
站设有引水隧洞两条,分别在桩号引l0+784.986、
引20+801.796处设两岔管洞将两洞分为四条高压支
管洞。单条引水隧洞总长约1148m。其中上、下斜井
长分别为387.6m和311.11TI,高差为490.4m。衬砌
内径为6.5~3.8ru,上、下斜井倾角均为50。。斜井
混凝土设计强度等级为C25W12F50(二级配),坍落
度设计值为70~90ram。经现场应用将坍落度提高至
10~12cm,同时采用人工砂和天然砂进行优化,优化
后的配合比满足施工需要。